Month: April 2018

Downloads

TitleSizeDownload
LCA-01, LCA-02, LCA-03 Pulp & Paper Datasheet SP - 041516 486.80 KB DownloadPreview
HydroACT Data Sheet 397.11 KB DownloadPreview
HydroACT 4 DuraTrac 3 Operations Manual 3.38 MB DownloadPreview
Quick Start Guide HydroACT 4 User Manual 0.97 MB DownloadPreview
HydroACT 4 DuraTrac 4 Operations Manual 3.47 MB DownloadPreview
HydroACT & DT4 - Data Sheet 867.55 KB DownloadPreview
Laboratory Charge Analyzer - LCA-01, LCA-02, LCA-03 Datasheet 2.89 MB DownloadPreview
Laboratory Charge Analyzer - Operations Manual 0.97 MB DownloadPreview
HydroACT 4 Chlorine Dioxide Operations Manual 3.33 MB DownloadPreview
HydroACT Residual Ozone Analyzer 353.95 KB DownloadPreview
Comparison Of On-Line Chlorine Analyzers 1.00 MB DownloadPreview
Understanding On-line Amperometric Chlorine Measurements 700.15 KB DownloadPreview
Free Chlorine Residual Hints & Tips 449.94 KB DownloadPreview
Membrane Cap Ordering Info 131.21 KB DownloadPreview
HydroACT 4 Ozone Operations Manual 3.33 MB DownloadPreview
HydroACT 4 Free Chlorine Operations Manual 3.39 MB DownloadPreview
HydroACT Residual Chlorine Analyzer – Data Sheet 1.12 MB DownloadPreview
HydroACT Residual Chlorine Dioxide Analyzer 447.94 KB DownloadPreview
Residual Chlorine Dioxide Analyzer 447.94 KB DownloadPreview
Particle Counter Firmware Update Procedure 459.95 KB DownloadPreview

Specifications

 HydroACT Features HA2 HA4 HA8
Power 100-240 VAC / 0.25 A or 12 VDC / 0.8 A (standard) or 24 VDC (optional)
Display 4.3”, 480×272, 8 bit, grayscale 4.3”, 480×272, 24 bit, color
Sensor Options Free Cl, Total Cl, Cl Dioxide, Chlorite, Ozone, pH with Temperature, ORP
SCM, UV254 organics, TSS/NTU, DO, Conductivity, Particle Counter
External Input (optional) 4-20 mA, 4-20 mA loop-powered, 0-2 VDC, 0-10 VDC, +/- 2000 mV for pH / ORP / ISEs, Pt100, pulse and Modbus
Analog Outputs (optional) Up to 2 Up to 4 Up to 8
Menu configurable outputs: 0-20 mA, 4-20 mA, 0-10 VDC, 0-1.25 VDC (Note: unused sensor inputs can be used as outputs)
Relays (optional) Up to 4 Up to 8 Up to 16
SPST, electromechanical, 380 VAC, 6 A max
Digital Inputs (optional) Up to 4 Up to 8 Up to 16
Alarms & Thresholds 2 user-configurable alarms & thresholds with deadband and delay for each parameter and control output
Control Loops (optional) Up to 2 Up to 4 Up to 8
Control Types (optional) High / Low Threshold PID (with start delay and SP ramping options), feed forward (NTU/UV),
flow pacing, high/low threshold, timer
Communication (optional) Modbus ASCII/RTU (RS485), Modbus TCP (Ethernet), PROFIBUS DP
Data & Event Logging 1,000 event / status records
stored in internal memory
1 million records stored internally
storage expandable with MicroSD card
Modem (optional) None GSM / GPRS / 3G intergrated modem
Remote Access (optional) None Internet browser access, alerts and reports via email (requires ethernet or modem card)
Enclosure ABS flame retardant, NEMA 4X / IP65
Dimensions & Weight HA2 & HA4: 9 in (230 mm) x 12.2 in (309 mm) x 4.1 in (103 mm); 4.4 lbs (2 kg)
HA8: 18 in (460 mm) x 12.2 in (309 mm) x 4.1 in (103 mm); 4.4 lbs (2 kg)

Description & Available Sensors

HydroACT Features HA2 HA4 HA8
Sensor limit* 2 4 8
Analog output limit* 2 4 8
Relay limit* 4 8 16
Digital Input limit* 4 8 16
Isolated universal I/O
Nema 4X/IP65
Wall & panel mount
Multilingual
High resolution display
Graphical trending
On/Off threshold control optional optional optional
Advanced control (e.g. PID) optional optional optional
Color display
Customizable data logs
MicroSD card download
Remote (Internet) access optional optional
PROFIBUS, Modbus optional optional

*Sensors, I/O, and relays are all optional and must be specified at time of ordering. See specifications on back for important details.

Sensors Ranges Number of Available Parameters
Free Chlorine 2, 5, 10, 20, 200 mg/L 1 (Free Cl)
Total Chlorine 2, 5, 10, 20 mg/L 1 (Total Cl)
Chlorine Dioxide 0.5, 2, 5, 10, 20 mg/L 1 (CIO2)
Chlorite 2 mg/L 1 (Chlorite)
 Ozone  0.2, 0.5, 2, 5, 10, 20 mg/L  1 (O3)
 pH with Temp 0-14 2 (pH, Temperature)
ORP -1999 to 1999 mV 1 (ORP)
 TSS/NTU  50-4,000 NTU, 0-20 g/L  3 (% solids, mg/L (or ppm), NTU)
 Streaming Current  -1000 to 1000 SCV  3 (SCV, Motor RPM, Signal Health)
UV254 0-100% UVT, 0-2 UVA 2 (UVT, UVA)
Conductivity 0-1,000 mS/cm2 2 (Conductivity, Temperature)
Torodial Conductivity 0-2,000 mS/cm2 2 (Conductivity, Temperature)
Dissolved Oxygen 0 to 50 mg/L
0-450% Saturation
3 (mg/L, % Saturation, Temp)
Particle Counter 2 to 100 micron 6 (Up to 6 Size Bins – counts or ppb)
External Inputs User Defined 1 (User Defined)

Connect With Us

Call Us

 
800.442.8722 or 770.449.6233

Meet Us

1555 Oakbrook Drive
Suite 100
Norcross, GA 30093
 
X