PC5000
weir-mount

Portable Particle Counter / Sampler

PC5000

The PC5000 Particle Counter/Portable Sampler has the capability to operate as both a grab sample particle counter (lab or field use) and an online particle counter, which makes it ideal for particle size and concentration analysis in a variety of municipal and industrial applications. The PC5000 can size particulates from 2 to 125 microns and count particulates from 2 to 750 microns. With the ability to detect particles at low part per trillion concentrations, the PC5000 offers superior analytical performance at an economical price compared to most other laboratory type particle counters.

The PC5000 Particle Counter/Portable Sampler combines simplicity of operation, advanced electronics, and powerful performance to set the standard for particle counting. This highly portable unit has the capability to operate as both a grab sample particle counter (lab or field use) and an online particle counter, which makes it ideal for particle size and concentration analysis in a variety of municipal and industrial applications. The PC5000 can size particulates from 2 to 125 microns and count particulates from 2 to 750 microns. With the ability to detect particles at low part per trillion concentrations, the PC5000 offers superior analytical performance at an economical price compared to most other laboratory type particle counters.

Standard Features

  • Online and grab sample operation
  • Built-in sample pump
  • Counts particles in liquid from 2-750 microns
  • Sizes particles from 2-125 microns
  • Up to 8 user programmable size ranges
  • Large display with 8 channel readout & graph
  • Reports total counts, cnts/mL, or cnts/100mL
  • Volumetric parts-per-billion (ppb) readout
  • Data download to PC via USB
  • User friendly, menu driven calibration
  • MODBUS RTU communication
  • Laser & cell condition readout (0-100%)
  • External sensor with sapphire optics

Optional Features

  • Flow control weir
  • TracWare online data acquisition software
  • Analog Outputs, Inputs, & Alarm Relays
  • MODBUS TCP (Ethernet)
  • Larger sizing capability upon request

Benefits

  • Quick and easy testing of grab samples
  • Can function as laboratory or online analyzer
  • Provides a reliable and accurate measurement of particles down to low ppt levels
  • Advanced firmware and menu functions eliminates need for external software to perform setup and calibration
  • User friendly calibration routine makes calibration fast, simple, and lowers maintenance cos

Laser Type

Solid-state laser diode (780 nm)

Cell Material

Nituff coated aluminum
PEEK plastic (optional)

Viewing Windows

Sapphire

Detection Range

2-750 microns

Sizing Range

2-125 microns

Flow Rate

75 mL/min

Size Channels

8 – user selectable and total counts

Count Format

User selectable; Counts per ml, Counts per 100 ml, or Raw Counts

Volumetric Readout

Parts-per-billion (ppb)

Laser Diode Life

MTBF 75,000 hours @ 55° C

Local Display

Graphical, 8 size channels displayed at once, unit info/diagnostic screen

Display Readout

Size channel, counts ppb, cell condition (0-100%), laser condition (0-100%), unit address, # of

stored data records, sample period, sample frequency, flow rate

Graphical Trending

Last 64 recorded readings, User selectable value trending (e.g. Total Counts, Bin 1, Cell Condition,

Analog Input, etc), Online mode only

Data Storage

>30,000 sample strings, User defined logging interval (1 – 254 min.) in Online mode

Up to 200 samples with 99 runs per sample in Grab mode

Keypad Interface

All instrument settings may be modified via the keypad interface, including instrument calibration

(some settings require password)

Serial Communications

2 wire RS485 (Network) and USB (Local)

Communication Protocols

Standard: MODBUS RTU (RS485)

Optional: MODBUS TCP (Ethernet)

Analog Outputs

2, 4, or 6 channels, 4-20 mA (optional) Online mode only

Analog Inputs

2, 4, or 6 channels, 0-5V, 0-10V, 0-20 mA, 4-20 mA (optional) Online mode only

Alarm Relays

1 Dry Contact Relay, 250V, 5A (optional) Online mode only

Power Requirements

100 or 240 VAC, 50 – 60 Hz, 1A

Operating Temperature: 32° – 120° F (0° – 50° C)

Dimensions

12” W x 11.5” H x 5.25” D (305 mm W x 292 mm H x 57 mm D)

Weight: 7 lbs (3.2 kg)

Weight

7 lbs (3.2 kg)

 *Can only have up to a maximum of 6 outputs & inputs

PC5000 / Operation Manuals Version Languages Size Date
PC5000 Operations Manual

PC5000 Operations Manual

v070615 1.3 MiB 07/07/2015
PC5000 / Datasheets Version Languages Size Date
PC5000 - Data Sheet

PC5000 – Data Sheet

247.5 KiB 09/05/2014
  • Chemtrac to Exhibit at ACE17 in Philadelphia Posted on: 05/25/2017
    The PC5000 Particle Counter/Portable Sampler combines simplicity of operation, advanced electronics, and powerful performance to set the standard for particle counting. This highly portable unit has the capability to operate as both a grab sample particle counter (lab or field use) and an online particle counter, which makes it ideal for particle size and concentration analysis in a variety of municipal and industrial applications. The PC5000 can size particulates from 2 to 125 microns and count particulates from 2 to 750 microns. With the ability to detect particles at low part per trillion concentrations, the PC5000 offers superior analytical performance at an economical price compared to most other laboratory type particle counters.
  • Another Successful Showcase at ACE 2016 Posted on: 07/30/2016

    The Chemtrac team joined attendees at ACE 2016 in Chicago, IL to discuss the latest models of Streaming Current Monitors, Particle Counters, Chlorine Analyzers, and HydroACT multi-parameter analyzer.   The Laboratory Charge Analyzer, a bench-top streaming current unit, was the featured product.

    As mentioned previously, the LCA builds on the success and solid performance of its predecessor models (CCA3100, ECA2100 and ECAT2100), allowing for charge neutralization titrations to accurately determine target coagulant dosages for surface water treatment. Essentially, the LCA provides a way for conducting jar tests in less than five minutes, as opposed to the traditional methods that can take in excess of an hour to run.

  • Introducing Next Generation Products at ACE16 Posted on: 06/14/2016

    We will be introducing our two new series of products at the 2016 AWWA Annual Conference & Exposition in Chicago next week (June 19-22). Both the Laboratory Charge Analyzers, and the third-generation HydroACT multi-parameter analyzers, will be revealed and on display at our Chemtrac Booth (#1040) in the ACE Exhibit Hall.

  • Happy Birthday Chemtrac, Inc. — Thirty One-derful Years! Posted on: 05/05/2016

    We are happy to say that this month marks the 31st anniversary of Chemtrac, Inc. Founded in 1985 upon the release of a new Streaming Current Monitor, Chemtrac has come a long way and is now recognized as one of the world’s leading manufacturers of Streaming Current Monitors and Particle Counters, as well as the provider of the HydroACT series of multi-parameter analyzers.

  • WWET Training on Particle Counts and Turbidity Posted on: 09/25/2015

    Chemtrac recently conducted a four-hour training class for Water Wastewater Education & Training (WWET), in Henderson, NV.  There were over 50 attendees from the local area. The group was mostly composed of operators from the City of Henderson, Las Vegas Valley Water District (LVVWD), Southern Nevada Water Authority (SNWA), and Southern Nevada Water Services (SNWS).

    The training was well received by those in attendance.  The WWET training coordinator, Brett Goodnow, had the following to say, “Chemtrac’s training was probably the best I have seen on those subjects. If found it very interesting that turbidity and particle counts do not always correlate. It was my impression that they would always complement each other. We had particle counters for years and now realize we did not fully understand their operating parameters, strengths and limitations.  Over the years we have had coagulation problems and filter performance issues that we could not figure out, but the information we received from your class really opened my eyes to some of those issues.”  

More News on Particle Counters

Residual Ozone Analyzer
Laboratory Charge Analyzer

SHOW YOUR SUPPORT

Chemtrac Incorporated
No portion of this site may be reproduced in any way without express permission of the publisher.